Ex RC Si M30
- Product Code: Ex RC Si M30
- Availability: In Stock
Ex RC Si M30
Features/Options
- Ex zone 1 and 21
- Metal enclosure
- Available in stainless steel enclosure
- Reed contacts, coded
- Actuation from front
- Switching distance up to 10 mm
- Special version only for gas Ex zone 2 and dust Ex zone 22 available
- N.B.: Please state required approvals for Russia and China with your order!
Note
The actuator is not included with the switches.
Product image
Technical data
Standards | EN ISO 13849-1; IEC/EN 60947-5-3 / PDF-M*; EN 954-1; EN 1088; EN 60079-0; EN 60079-18; EN 61241-0; EN 61241-1 |
---|---|
Enclosure | aluminium brass, nickeled or stainless steel 1.4571 |
Actuator | Ex MC 30 or Ex MC 30-NIRO |
Degree of protection | IP 67 to IEC/EN 60529 or IP 69 K |
Switching system | Reed contacts |
Contact types | 1 NC/1 NO contact or 2 NC contacts |
Connection | cable H05 VV-F 5G, 5 x 0.5 mm² |
Cable length | 1, 2, 5 or 10 m |
B10d (10% Load) | 1 million |
TM | max. 20 years |
MTTFd | >100 years |
Ie/Ue | max. 125 mA, with LED: 20 mA / |
Switching voltage | max. 30 VDC |
Voltage drop at Ie | 2.5 V, with LED: 3 V |
Switching frequency | 5 Hz |
Ambient temperature | -20 °C … +70 ºC |
Mechanical life | > 10 million operations |
Repeatability | < 0.5 mm |
Operating distances: | |
smax | 10 mm |
sao | 8 mm |
sar | 24 mm |
Ex marking | II 2G Ex mb II T6, II 2D Ex tD A21 IP67 T80°C IECEx Ex mb II T6, Ex tD A21 IP67 T80°C |
Approvals | PTB 05 ATEX 2024 X; IECEx PTB 07.0008 X |