Code: |
|
|
Name:
|
2 Ch, Switch/Proximity Detector Repeater, Transistor Out, SIL 2
|
|
Type:
|
|
|
Supply:
|
24 Vdc
|
|
Field device:
|
|
|
Channels:
|
2
|
|
Description:
|
The D1033D isolates and repeat two contacts or two proximity detectors in Hazardous Location, providing four O.C. Transistor outputs to drive Safe Area Loads. Two of the O.C. outputs can be configured to remotely signal Lead Breakage/Fault Detection. The unit can be configured for NO/NC contact or proximity detector inputs and for NO or ND optocoupled open collector transistor output. Suitable for application requiring SIL 2 level (according to EN61508).
|
|
Hazardous area:
|
Dry contact, proximity Switch.
|
|
Safe area:
|
1 Open collector per channel plus 1 Open Collector and LED for line fault detection
|
|
Function:
|
2 channels I.S. switch repeater for contact or EN60947-5-6 Proximity Switches. Provides 3 port isolation (input/output/supply). Line-fault detection, common to all input signals, available when using enclosures with Power bus.
|
|
Features:
|
• Field Configurable via Dip-Switches.
• Remote signaling of fault detection.
• Fully Floating Channels
• High operating frequency.
• Independent remote fault signaling
|
|
SIL level:
|
D1033D, according IEC 61508 & IEC 61511, is suitable for applications up to safety integrity level SIL 2 .
Please see our Functional Safety Manual for details.
|
|
Datasheet:
|
|
DTS0151 |
D1033D English datasheet (PDF 262 KB) |
|
|
DTS0297 |
D1033D Italiano datasheet (PDF 305 KB) |
|
|
DTS0210 |
D1033D Pусский datasheet (PDF 91 KB) |
|
|
|
Instruction manual:
|
|
ISM0043 |
D1033D instruction manual (PDF 710 KB) |
|
|
ISM0071 |
Functional Safety manual for SIL 2, SIL 3 applications (PDF 554 KB) |
|
|
ISM0075 |
Installation of Electronic Equipments in Cabinets (PDF 78 KB) |
|
|
ISM0102 |
General D1000 Series Instruction Manual (PDF 2.39 MB) |
|
|
ISM0092 |
Russian language Functional Safety manual for SIL 2, SIL 3 applications (PDF 525 KB) |
|
|
|
Certifications:
|
|
CRT003 |
ATEX DMT 01 ATEX E 042 X (PDF 5.56 MB) |
|
|
CRT005 |
UL & C-UL (PDF 57 KB) |
|
|
CRT008 |
TCCExEE for D1000 Series (Russia) (PDF 492 KB) |
|
|
CRT009 |
TCCExEE for D1000 Series (Ukraine) (PDF 626 KB) |
|
|
CRT010 |
Rostehnadzor for D1000 Series (Russia) (PDF 149 KB) |
|
|
CRT011 |
Gosstandard for D1000 Series (Russia) (PDF 953 KB) |
|
|
CRT012 |
Gosnadzorohrantruda for D1000 Series (Ukraine) (PDF 168 KB) |
|
|
CRT013 |
EXIDA SIL2 SIL3 Analysis (03/07-24) (PDF 408 KB) |
|
|
CRT014 |
Metrological Certificate for D1000 Series (Russia) (PDF 307 KB) |
|
|
CRT020 |
FM 3024643 (USA) & FM-C 3029921C (Canada) (PDF 6.20 MB) |
|
|
CRT023 |
DNV Certificate for Ships and Offshore Standards (PDF 282 KB) |
|
|
CRT028 |
Korean Register Type Approval Certificate (PDF 460 KB) |
|
|
CRT032 |
IECEx Certificate for D1000 Series (PDF 1.77 MB) |
|
|
CRT035 |
TÜV SIL Certificate Summary (PDF 555 KB) |
|
|
CRT044 |
TÜV SIL Report for D1033 (PDF 1.02 MB) |
|
|
CRT047 |
ATEX Certificate D1000 Series by IMQ (PDF 1.02 MB) |
|
|
|
Application notes:
|
|
APN0007 |
Universal AC Power Supply for Series D1000 (PDF 44 KB) |
|
|
APN0010 |
Digital Unit Testing for D1000 Models (PDF 212 KB) |
|
|
|
Accessories:
|
BUS |
Power Bus Optional Enclosure |
|
|