Code: |
|
|
Name:
|
Repeater Power Supply Smart Compatible DIN Rail, SIL 3
|
|
Type:
|
|
|
Supply:
|
24 Vdc
|
|
Field device:
|
|
|
Channels:
|
1
|
|
Description:
|
The single channel DIN Rail Repeater Power Supply, D1010S-046, provides a fully floating dc supply for energizing conventional 2-wire 4-20 mA
Transmitter, or separately powered 3,4-wire 4-20 mA 0-20 Transmitter located in Hazardous Area, and repeats the current in floating circuit to
drive a Safe Area Load. The Circuit allowes bi-directional communication signals, for Hart Transmitters.
|
|
Hazardous area:
|
4-20 mA/0-20 mA (14 V) floating supply and signal to Smart, or non Smart, two-three wire Tx.
|
|
Safe area:
|
4-20 mA/0-20 mA source or sink or 1-5 V/0-5 V output signal totally isolated from Input and Supply.
|
|
SIL level:
|
D1010S-046, according IEC 61508 & IEC 61511, is suitable for applications up to safety integrity level SIL 3 .
Please see our Functional Safety Manual for details.
|
|
Datasheet:
|
|
DTS0188 |
D1010S-046 English datasheet (PDF 325 KB) |
|
|
DTS0291 |
D1010S-046 Italiano datasheet (PDF 402 KB) |
|
|
|
Instruction manual:
|
|
ISM0066 |
D1010S-046 instruction manual (PDF 844 KB) |
|
|
ISM0075 |
Installation of Electronic Equipments in Cabinets (PDF 78 KB) |
|
|
ISM0102 |
General D1000 Series Instruction Manual (PDF 2.39 MB) |
|
|
ISM0092 |
Russian language Functional Safety manual for SIL 2, SIL 3 applications (PDF 525 KB) |
|
|
|
Certifications:
|
|
CRT003 |
ATEX DMT 01 ATEX E 042 X (PDF 5.56 MB) |
|
|
CRT010 |
Rostehnadzor for D1000 Series (Russia) (PDF 149 KB) |
|
|
CRT013 |
EXIDA SIL2 SIL3 Analysis (03/07-24) (PDF 408 KB) |
|
|
CRT014 |
Metrological Certificate for D1000 Series (Russia) (PDF 307 KB) |
|
|
CRT032 |
IECEx Certificate for D1000 Series (PDF 1.77 MB) |
|
|
CRT047 |
ATEX Certificate D1000 Series by IMQ (PDF 1.02 MB) |
|
|
|
Application notes:
|
|
APN0007 |
Universal AC Power Supply for Series D1000 (PDF 44 KB) |
|
|
|
Various:
|
|
|
|