‘FP-C’ Removable Core Immersion Heaters
- Product Code: FP-C Removable Core
- Availability: In Stock
‘FP-C’ Removable Core Immersion Heaters
The EXHEAT FP range of Flameproof removable single and multi core heaters offers a Hazardous Area heating solution for oil and similar applications where low heat density is required. The element can be withdrawn for inspection without system drain down. The standard heater consists of a single element or multi core fitted into a mounting flange. A robust Ex‘d’ terminal enclosure protects the electrical connections. The watts density of the element core fitted depends upon the media to be heated and the kilowatt rating required.
Downloads:
Datasheet: ex-baltic.com/files/FP-C_Hazardous-Area-Flameproof-Industrial-Immersion-Heater.pdf
ATEX Certificate: ex-baltic.com/files/LCIE-01-ATEX-6056-X-4.pdf
Installation Manual: ex-baltic.com/files/iom-industrial-immersion-heater-3.pdf
Single Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht10.pdf
Two Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht11.pdf
Three Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht12.pdf
Six Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht13_14.pdf
Nine Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht15_16.pdf
Datasheet: ex-baltic.com/files/FP-C_Hazardous-Area-Flameproof-Industrial-Immersion-Heater.pdf
ATEX Certificate: ex-baltic.com/files/LCIE-01-ATEX-6056-X-4.pdf
Installation Manual: ex-baltic.com/files/iom-industrial-immersion-heater-3.pdf
Single Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht10.pdf
Two Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht11.pdf
Three Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht12.pdf
Six Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht13_14.pdf
Nine Core Type Wiring Diagram: ex-baltic.com/files/3034-01-S1-01-Sht15_16.pdf
Features
Certified to meet the requirements of the ATEX Directive 94/9/EC and IECEx
Mild steel or 316 stainless steel terminal enclosure with weatherproof protection to IP65
Choice of built in process temperature sensors
Suitable for ambient temperatures from -50°C to +60°C
Mounting of the heater can be by a threaded boss or an industry standard flange
Designed for horizontal installation (vertical mounting version available on request)
Can be supplied with the terminal box mounted away from the fixing boss/flange for high process temperatures
Typical Applications
Pre-heating oil/water
Processing equipment
Cleaning and rinsing tanks
Heat transfer systems
Boiler equipment
Frost protection
Specification
Certification
ATEX certified Ex II 2 G/D
IECEx & ATEX certified Ex’d’ IIC T1 to T6 Ex tD A21 IP66 T450 to 85°C
EN/IEC60079-0, EN/IEC60079-1, EN/IEC61241-0 & EN/IEC61241-1
CCOE (India) & KGS (Korea)
IECEx & ATEX certified Ex’d’ IIC T1 to T6 Ex tD A21 IP66 T450 to 85°C
EN/IEC60079-0, EN/IEC60079-1, EN/IEC61241-0 & EN/IEC61241-1
CCOE (India) & KGS (Korea)
Enclosure
Mild steel or 316 stainless steel, external and internal earths, screwed terminal cover, finished in epoxy paint (if required)
Elements
Removable core, comprising high quality 80/20 nickel chrome resistance wire, contained within ceramic formers housed in plain or extended surface tubes
Controls
Heater over-temperature protection is fitted as standard (optional process temperature sensing devices can be incorporated in the form of thermostats, RTD’s or thermocouples)
Mounting
Any threaded boss or flange in any material can be specified within the limits of the design parameters
Heater terminal box can be either ‘direct-on’ or ‘stand-off’, depending on process temperature
Heater terminal box can be either ‘direct-on’ or ‘stand-off’, depending on process temperature
Rating
To suit process requirement within the design parameters and ATEX approval
Voltage
Any electrical supply up to 690V